manufacturer:
Number of Outputs:
Voltage - Isolation:
Voltage - Output 2:
Voltage - Output 3:
Odonata Lepidoptera products 104
Image part manufacturer quantitas partus tempus Unit Price buy Description Series Applications Operating Temperature Mounting Type Type Power (Watts) Size / Dimension Voltage - Input Number of Outputs Current - Output (Max) Voltage - Isolation Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Efficiency
LPT103-M
Artesyn Embedded Technologies
217
III dies
-
MOQ: 1  MPQ: 1
AC/DC CONVERTER 5V +/-15V 80W
LPT100-M ITE (Commercial),Medical 0°C ~ 70°C (With Derating) Chassis Mount Open Frame 80W (130W Forced Air) 4.00" L x 2.00" W x 1.28" H (102.0mm x 51.0mm x 32.6mm) 90 ~ 264 VAC 3 18A,7.2A,1.5A - 5V 15V -15V 0.82
LPT102-M
Artesyn Embedded Technologies
179
III dies
-
MOQ: 1  MPQ: 1
AC/DC CONVERTER 5V +/-12V 80W
LPT100-M ITE (Commercial),Medical 0°C ~ 70°C (With Derating) Chassis Mount Open Frame 80W (130W Forced Air) 4.00" L x 2.00" W x 1.28" H (102.0mm x 51.0mm x 32.6mm) 90 ~ 264 VAC 3 18A,9A,2.3A - 5V 12V -12V 0.82
LPT104-M
Artesyn Embedded Technologies
107
III dies
-
MOQ: 1  MPQ: 1
AC/DC CONVERTER 5V 24V 12V 80W
LPT100-M ITE (Commercial),Medical 0°C ~ 70°C (With Derating) Chassis Mount Open Frame 80W (130W Forced Air) 4.00" L x 2.00" W x 1.28" H (102.0mm x 51.0mm x 32.6mm) 90 ~ 264 VAC 3 18A,3A,2.3A - 5V 24V 12V 0.82
JWS10028/A
TDK-Lambda Americas Inc.
61
III dies
-
MOQ: 1  MPQ: 1
AC/DC CONVERTER 28V 100W
JWS ITE (Commercial) -10°C ~ 60°C (With Derating) Chassis Mount Enclosed 100W 7.40" L x 3.62" W x 1.97" H (188.0mm x 91.9mm x 50.0mm) 85 ~ 265 VAC 1 3.6A 3kV 28V - - 0.79
LPT101-M
Artesyn Embedded Technologies
53
III dies
-
MOQ: 1  MPQ: 1
AC/DC CONVERTER 3.3V 5V 12V 80W
LPT100-M ITE (Commercial),Medical 0°C ~ 70°C (With Derating) Chassis Mount Open Frame 80W (130W Forced Air) 4.00" L x 2.00" W x 1.28" H (102.0mm x 51.0mm x 32.6mm) 90 ~ 264 VAC 3 18A,9A,2.3A - 3.3V 5V 12V 0.82
JWS30012
TDK-Lambda Americas Inc.
62
III dies
-
MOQ: 1  MPQ: 1
AC/DC CONVERTER 12V 300W
JWS ITE (Commercial) -10°C ~ 65°C (With Derating) Chassis Mount Enclosed 300W 7.48" L x 4.72" W x 3.62" H (190.0mm x 120.0mm x 92.0mm) 85 ~ 265 VAC 1 27A 3kV 12V - - 0.76
LPS45-M
Artesyn Embedded Technologies
112
III dies
-
MOQ: 1  MPQ: 1
AC/DC CONVERTER 24V 40W
LPS40-M Medical 0°C ~ 70°C (With Derating) Chassis Mount Open Frame 40W (55W Forced Air) 5.00" L x 3.00" W x 1.14" H (127.0mm x 76.2mm x 29.0mm) 85 ~ 264 VAC 1 1.6A - 24V - - 0.7
JWS30028
TDK-Lambda Americas Inc.
15
III dies
-
MOQ: 1  MPQ: 1
AC/DC CONVERTER 28V 300W
JWS ITE (Commercial) -10°C ~ 65°C (With Derating) Chassis Mount Enclosed 300W 7.48" L x 4.72" W x 3.62" H (190.0mm x 120.0mm x 92.0mm) 85 ~ 265 VAC 1 12A 3kV 28V - - 0.8
JWS10012/A
TDK-Lambda Americas Inc.
9
III dies
-
MOQ: 1  MPQ: 1
AC/DC CONVERTER 12V 100W
JWS ITE (Commercial) -10°C ~ 60°C (With Derating) Chassis Mount Enclosed 100W 7.40" L x 3.62" W x 1.97" H (188.0mm x 91.9mm x 50.0mm) 85 ~ 265 VAC 1 8.5A 3kV 12V - - 0.76
JWS15024/A
TDK-Lambda Americas Inc.
13
III dies
-
MOQ: 1  MPQ: 1
AC/DC CONVERTER 24V 150W
JWS ITE (Commercial) -10°C ~ 60°C (With Derating) Chassis Mount Enclosed 150W 7.80" L x 3.62" W x 2.56" H (198.1mm x 91.9mm x 65.0mm) 85 ~ 265 VAC 1 6.5A 3kV 24V - - 0.8
JWS30024
TDK-Lambda Americas Inc.
5
III dies
-
MOQ: 1  MPQ: 1
AC/DC CONVERTER 24V 300W
JWS ITE (Commercial) -10°C ~ 65°C (With Derating) Chassis Mount Enclosed 300W 7.48" L x 4.72" W x 3.62" H (190.0mm x 120.0mm x 92.0mm) 85 ~ 265 VAC 1 14A 3kV 24V - - 0.8
JWS60024
TDK-Lambda Americas Inc.
3
III dies
-
MOQ: 1  MPQ: 1
AC/DC CONVERTER 24V 600W
JWS ITE (Commercial) -10°C ~ 65°C (With Derating) Chassis Mount Enclosed 600W 7.90" L x 6.29" W x 3.62" H (200.6mm x 159.8mm x 92.0mm) 85 ~ 265 VAC 1 27A 3kV 24V - - 0.82
HWS100A12/ME
TDK-Lambda Americas Inc.
12
III dies
-
MOQ: 1  MPQ: 1
AC/DC CONVERTER 12V 100W
HWS100A/A ITE (Commercial),Medical -10°C ~ 70°C (With Derating) Chassis Mount Open Frame 100W 6.30" L x 3.23" W x 1.30" H (160.0mm x 82.0mm x 33.0mm) 85 ~ 265 VAC 1 8.5A 3kV 12V - - 0.88
HWS100A24/ME
TDK-Lambda Americas Inc.
5
III dies
-
MOQ: 1  MPQ: 1
AC/DC CONVERTER 24V 100W
HWS100A/A ITE (Commercial),Medical -10°C ~ 70°C (With Derating) Chassis Mount Open Frame 100W 6.30" L x 3.23" W x 1.30" H (160.0mm x 82.0mm x 33.0mm) 85 ~ 265 VAC 1 4.5A 3kV 24V - - 0.89
HWS150A24/ME
TDK-Lambda Americas Inc.
18
III dies
-
MOQ: 1  MPQ: 1
AC/DC CONVERTER 24V 150W
HWS150A/A ITE (Commercial),Medical -10°C ~ 70°C (With Derating) Chassis Mount Open Frame 150W 6.30" L x 3.23" W x 1.65" H (160.0mm x 82.0mm x 42.0mm) 85 ~ 265 VAC 1 6.5A 3kV 24V - - 0.9
HWS150A48/ME
TDK-Lambda Americas Inc.
5
III dies
-
MOQ: 1  MPQ: 1
AC/DC CONVERTER 48V 150W
HWS150A/A ITE (Commercial),Medical -10°C ~ 70°C (With Derating) Chassis Mount Open Frame 150W 6.30" L x 3.23" W x 1.65" H (160.0mm x 82.0mm x 42.0mm) 85 ~ 265 VAC 1 3.3A 3kV 48V - - 0.91
JWS10024/A
TDK-Lambda Americas Inc.
5
III dies
-
MOQ: 1  MPQ: 1
AC/DC CONVERTER 24V 100W
JWS ITE (Commercial) -10°C ~ 60°C (With Derating) Chassis Mount Enclosed 100W 7.40" L x 3.62" W x 1.97" H (188.0mm x 91.9mm x 50.0mm) 85 ~ 265 VAC 1 4.5A 3kV 24V - - 0.79
JWS1005/A
TDK-Lambda Americas Inc.
3
III dies
-
MOQ: 1  MPQ: 1
AC/DC CONVERTER 5V 100W
JWS ITE (Commercial) -10°C ~ 60°C (With Derating) Chassis Mount Enclosed 100W 7.40" L x 3.62" W x 1.97" H (188.0mm x 91.9mm x 50.0mm) 85 ~ 265 VAC 1 20A 3kV 5V - - 0.75
JWS10015/A
TDK-Lambda Americas Inc.
8
III dies
-
MOQ: 1  MPQ: 1
AC/DC CONVERTER 15V 100W
JWS ITE (Commercial) -10°C ~ 60°C (With Derating) Chassis Mount Enclosed 100W 7.40" L x 3.62" W x 1.97" H (188.0mm x 91.9mm x 50.0mm) 85 ~ 265 VAC 1 7A 3kV 15V - - 0.77
JWS1505/A
TDK-Lambda Americas Inc.
2
III dies
-
MOQ: 1  MPQ: 1
AC/DC CONVERTER 5V 150W
JWS ITE (Commercial) -10°C ~ 60°C (With Derating) Chassis Mount Enclosed 150W 7.80" L x 3.62" W x 2.56" H (198.1mm x 91.9mm x 65.0mm) 85 ~ 265 VAC 1 30A 3kV 5V - - 0.75