- Applications:
-
- Operating Temperature:
-
- Type:
-
- Features:
-
- Power (Watts):
-
- Voltage - Input:
-
- Current - Output (Max):
-
- Voltage - Isolation:
-
Odonata Lepidoptera products 17
Image | part | manufacturer | quantitas | partus tempus | Unit Price | buy | Description | Series | Applications | Operating Temperature | Type | Features | Power (Watts) | Voltage - Input | Current - Output (Max) | Voltage - Isolation | Efficiency | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Image | part | manufacturer | quantitas | partus tempus | Unit Price | buy | Description | Series | Applications | Operating Temperature | Type | Features | Power (Watts) | Voltage - Input | Current - Output (Max) | Voltage - Isolation | Efficiency | ||
Cosel USA,Inc. |
40
|
III dies |
-
|
MOQ: 1 MPQ: 1
|
3X5 SWITCHING POWER SUPPLIES AC/
|
GHA | ITE (Commercial),Medical | -20°C ~ 80°C (With Derating) | Open Frame | Adjustable Output,PFC,Universal Input | 100W (300W Forced Air) | 90 ~ 264 VAC | 2.1A | 4kV | 0.91 | ||||
Cosel USA,Inc. |
40
|
III dies |
-
|
MOQ: 1 MPQ: 1
|
3X5 SWITCHING POWER SUPPLIES AC/
|
GHA | ITE (Commercial),Medical | -20°C ~ 80°C (With Derating) | Open Frame | Adjustable Output,DC Input Capable,Universal Input | 150W (500W Forced Air) | 90 ~ 264 VAC | 3.2A | 4kV | 0.91 | ||||
Cosel USA,Inc. |
10
|
III dies |
-
|
MOQ: 1 MPQ: 1
|
3X5 SWITCHING POWER SUPPLIES 504
|
GHA | ITE (Commercial),Medical | -20°C ~ 80°C (With Derating) | Open Frame | Adjustable Output,DC Input Capable,PFC,Remote On/Off,Standby Output,Universal Input | 150W (500W Forced Air) | 90 ~ 264 VAC | 3.2A | 4kV | 0.91 | ||||
Cosel USA,Inc. |
20
|
III dies |
-
|
MOQ: 1 MPQ: 1
|
3X5 SWITCHING POWER SUPPLIES 504
|
GHA | ITE (Commercial),Medical | -20°C ~ 80°C (With Derating) | Enclosed | Adjustable Output,DC Input Capable,PFC,Universal Input | 504W | 90 ~ 264 VAC | 10.5A | 4kV | 0.91 | ||||
CUI Inc. |
Quaestiones
|
- |
-
|
MOQ: 1 MPQ: 1
|
AC/DC CONVERTER 48V 111W/185W
|
VOF-185 | ITE (Commercial) | -20°C ~ 70°C (With Derating) | Open Frame | Adjustable Output,PFC,Standby Output,Universal Input | 111W (185W Forced Air) | 90 ~ 277 VAC | 3.85A | 3kV | 0.85 | ||||
CUI Inc. |
Quaestiones
|
- |
-
|
MOQ: 1 MPQ: 1
|
AC/DC CONVERTER 48V 135W/225W
|
VOF-225 | ITE (Commercial) | -20°C ~ 70°C (With Derating) | Open Frame | Adjustable Output,PFC,Standby Output,Universal Input | 135W (225W Forced Air) | 90 ~ 277 VAC | 4.69A | 3kV | 0.91 | ||||
CUI Inc. |
Quaestiones
|
- |
-
|
MOQ: 1 MPQ: 1
|
AC/DC CONVERTER 48V 168W/280W
|
VOF-280 | ITE (Commercial) | -20°C ~ 70°C (With Derating) | Open Frame | Adjustable Output,PFC,Standby Output,Universal Input | 168W (280W Forced Air) | 90 ~ 277 VAC | 5.84A | 3kV | 0.91 | ||||
Cosel USA,Inc. |
Quaestiones
|
- |
-
|
MOQ: 1 MPQ: 1
|
AC/DC PS (OPEN FRAME)
|
GHA | ITE (Commercial),Medical | -20°C ~ 80°C (With Derating) | Open Frame | Adjustable Output,PFC,Universal Input | 100W (300W Forced Air) | 90 ~ 264 VAC | 2.1A | 4kV | 0.91 | ||||
Cosel USA,Inc. |
Quaestiones
|
- |
-
|
MOQ: 1 MPQ: 1
|
AC/DC PS (OPEN FRAME)
|
GHA | ITE (Commercial),Medical | -20°C ~ 80°C (With Derating) | Open Frame | Adjustable Output,PFC,Universal Input | 100W (300W Forced Air) | 90 ~ 264 VAC | 2.1A | 4kV | 0.91 | ||||
Cosel USA,Inc. |
Quaestiones
|
- |
-
|
MOQ: 1 MPQ: 1
|
AC/DC PS (OPEN FRAME)
|
GHA | ITE (Commercial),Medical | -20°C ~ 80°C (With Derating) | Open Frame | Adjustable Output,DC Input Capable,PFC,Remote On/Off,Standby Output,Universal Input | 100W (300W Forced Air) | 90 ~ 264 VAC | 2.1A | 4kV | 0.91 | ||||
Cosel USA,Inc. |
Quaestiones
|
- |
-
|
MOQ: 1 MPQ: 1
|
AC/DC PS (OPEN FRAME)
|
GHA | ITE (Commercial),Medical | -20°C ~ 80°C (With Derating) | Open Frame | Adjustable Output,DC Input Capable,Universal Input | 150W (500W Forced Air) | 90 ~ 264 VAC | 3.2A | 4kV | 0.91 | ||||
Cosel USA,Inc. |
Quaestiones
|
- |
-
|
MOQ: 1 MPQ: 1
|
AC/DC PS (OPEN FRAME)
|
GHA | ITE (Commercial),Medical | -20°C ~ 80°C (With Derating) | Open Frame | Adjustable Output,DC Input Capable,Load Sharing,PFC,Universal Input | 150W (500W Forced Air) | 90 ~ 264 VAC | 3.2A | 4kV | 0.91 | ||||
Cosel USA,Inc. |
Quaestiones
|
- |
-
|
MOQ: 1 MPQ: 1
|
AC/DC PS (OPEN FRAME)
|
GHA | ITE (Commercial),Medical | -20°C ~ 80°C (With Derating) | Open Frame | Adjustable Output,DC Input Capable,Universal Input | 150W (500W Forced Air) | 90 ~ 264 VAC | 3.2A | 4kV | 0.91 | ||||
Mean Well USA Inc. |
34
|
III dies |
-
|
MOQ: 1 MPQ: 1
|
O/P +48V8.4A
|
EPP-400 | ITE (Commercial) | -30°C ~ 70°C (With Derating) | Open Frame | Adjustable Output,PFC,Remote Sense,Universal Input | 254W (403W Forced Air) | 80 ~ 264 VAC,113 ~ 370 VDC | 5.3A | 3kV | 0.9399999999999999 | ||||
Mean Well USA Inc. |
Quaestiones
|
- |
-
|
MOQ: 1 MPQ: 1
|
O/P +48V6.25A
|
EPP-300 | ITE (Commercial) | -30°C ~ 70°C (With Derating) | Open Frame | Adjustable Output,PFC,Remote Sense,Universal Input | 200W (300W Forced Air) | 90 ~ 264 VAC,127 ~ 370 VDC | 4.17A | 3kV | 0.93 | ||||
GE Critical Power |
Quaestiones
|
- |
-
|
MOQ: 1 MPQ: 1
|
CLP0448FPXXXZ01A 450W OPEN FRAME
|
CLP | ITE (Commercial) | -40°C ~ 85°C (With Derating) | Open Frame | Remote On/Off,Remote Sense,Standby Output,Universal Output | 451W | 90 ~ 265 VAC | 9.4A | 3kV | 0.92 | ||||
Bel Power Solutions |
Quaestiones
|
- |
-
|
MOQ: 1 MPQ: 1
|
AC/DC CONVERTER 48V 75W
|
PLP75 | ITE (Commercial) | -20°C ~ 70°C (With Derating) | Open Frame | Adjustable Output,PFC,Universal Input | 75W | 85 ~ 264 VAC | 1.4A | 4.242kV | 0.8 |